Products

PTP Precision Time Protocol

DNWP connection master supports synchronization distribution and PTP profiles defined by ITU-T, IEEE and IEC standards.

Boundary and Transparent Clock modes can be selected. For best performance, PTP can be used together with SyncE.

  • G.8275.1 – Precision time protocol telecom profile for
    phase/time synchronization with full timing support from the network.
  • G.8275.2 – Precision time protocol telecom profile for
    phase/time synchronization with partial timing support from the network.
  • G.8265.1 – Precision time protocol telecom profile for
    frequency synchronization.
  • C37.238-2017 – Precision time protocol in power system
    applications.
  • 61850-9-3:2016 – Precision time protocol profile for power
    utility automation.

Adjustable port ingress/egress latency

Maximum absolute time error – TE: 30 ns (G.8273.2)
Maximum constant time error – cTE: 10 ns (G.8273.2)

Other supported frequency sources and outputs

  • Synchronous Ethernet (SyncE; ITU-T G.8261)
  • E1, 2.048 Mbps
  • 2.048 MHz

PTP Profile Comparison Table

Standard Industry Primary Goal Transport Key Advantage
G.8275.1 Telecom Phase / Time L2 Multicast Highest accuracy over private fiber networks.
G.8275.2 Telecom Phase / Time L3 Unicast Works over third-party or legacy non-PTP routers.
G.8265.1 Telecom Frequency Only L3 Unicast Frequency delivery for IP-routed networks.
IEC 61850-9-3 Power Phase / Time L2 Multicast PTP profile for IEC 61850 digital substations.
IEEE C37.238-2017 Power Phase / Time L2 Multicast IEC 61850-9-3 compatible, with dynamic time-inaccuracy monitoring.